Ad-hoc

Activate1

Unconfirmed

The field format for this command is unknown and is guessed from Activate2.

Field Size Note
Code 1 0x??
IDm 8
Flags? 1
Field Size Note
Code 1 0x??
IDm 8
Status? 1

Activate212

Unconfirmed

The field format for this command is unknown and is guessed.

Field Size Note
Code 1 0xA4
IDm 8
Flags? 1
Field Size Note
Code 1 0xA5
IDm 8
Status? 1

Inactivate1

Unconfirmed

The field format for this command is unknown and is guessed from Activate2.

Field Size Note
Code 1 0x??
IDm 8
Flags? 1
Field Size Note
Code 1 0x??
IDm 8
Status? 1

Push12

Field Size Note
Code 1 0xB0
IDm 8
Length 1 \(1 <= n <= 224\)
Data \(n\)
Field Size Note
Code 1 0xB1
IDm 8
Length Received 1

Pull1

Unconfirmed

The field format for this command is unknown and is guessed from Push.

Field Size Note
Code 1 0x??
IDm 8
Maximum Length 1 \(1 <= n <= 224\)
Field Size Note
Code 1 0xB1
IDm 8
Length 1 \(1 <= n <= 224\)
Data \(n\)

Get Ad-hoc Status1

Unconfirmed

The field format for this command is unknown and is guessed.

Field Size Note
Code 1 0x??
IDm 8
Field Size Note
Code 1 0xA5
IDm 8
Status? 1

  1. 昭彦 山形 and 顕 深田. Icカード及び情報処理端末、3者間データ通信システム及び方法. February 2005. URL: https://patents.google.com/patent/JP3617509B2/ja (visited on 2024-06-18). 